China Cable Factory
11kV YJV32 SWA Cable 8.7/15 kV Three-Core Copper XLPE Steel Wire Armoured Cable

8.7/15 kV Three-Core Copper XLPE Steel Wire Armoured Cable

11kV YJV32 SWA Cable

Configuration-specific factory supply page for 8.7/15 kV three-core YJV32 enquiries

This page is limited to the published YJV32 configuration: three-core copper conductor, XLPE insulation and fine steel wire armour in the 8.7/15 kV class. It is a product and RFQ page; installation and cable-sizing guidance remains in the site's technical guides.

IEC 60502-2GB/T 12706

What is 11kV YJV32 SWA Cable?

The table below is not a generic armour table. It is restricted to the Huanghe catalogue's 8.7/15 kV, three-core, copper YJV32 configuration so that dimensions and weights are not mixed with unarmoured, aluminium or different-voltage products.

Sizing, derating and installation methods are intentionally outside this page's search target. Use the linked engineering guide for those questions and this page for the product configuration and quotation.

Key features

  • YJV32 three-core copper construction
  • XLPE insulation with fine steel wire armour
  • Nominal sections from 25 to 400 mm² in the published table
  • Dimensions and weights shown exactly as published
  • Order configuration confirmed against the purchaser's specification

Typical applications

  • Buried distribution circuits specified for three-core YJV32
  • Industrial incoming feeders requiring a steel-wire-armoured construction
  • Medium-voltage project circuits specified for the 8.7/15 kV class

YJV32 8.7/15 kV — Three-Core Copper SWA

Source: Huanghe factory data

Values are reproduced as published in the Huanghe LV/MV power cable catalogue, p.15.

Custom sizes available on request — send us your project specification.

Nominal Section (mm²)Overall Dia. (mm)Weight (kg/km)Current — In Ground (A)Current — In Air (A)
2554.54797156144
3556.95297186175
5059.76015220210
7063.66999269263
9567.58104322319
12071.09191365368
15074.710455410419
18580.212781463480
24086.015109535565
30090.817372602647
40098.721197683751

Information needed for an 8.7/15 kV YJV32 quotation

  • Confirm 8.7/15 kV on the project specification
  • State the required nominal section
  • State the required cable length for each size
  • State the outer-sheath requirement on the project specification
  • Provide the destination port and required inspection documents
  • If aluminium conductor is required, request the YJLV32 configuration instead

11kV YJV32 SWA Cable gallery

Three-core copper XLPE steel wire armoured cable construction sample
Multi-core steel wire armoured cable cross-section
Steel wire armouring line in the cable factory
Finished cable drums in the factory warehouse

Factory & delivery capability

Real photos from our production facility — from raw material to container loading.

Cable production line in China factory

Production Line

Quality testing laboratory for power cables

Quality Testing

Cable warehouse with finished products on wooden drums

Warehouse & Stock

Cable drum packaging ready for container loading

Drum Packaging

Cable drums loaded into shipping container for export

Container Loading

Completed shipment of power cables in 40ft container

Ready to Ship

Frequently asked questions about 11kV YJV32 SWA Cable

Q.What exact configuration is listed on this page?

The table is for 8.7/15 kV three-core YJV32: copper conductor, XLPE insulation and fine steel wire armour.

Q.Does the table also apply to aluminium conductor cable?

No. YJV32 identifies the copper-conductor configuration. Ask for the corresponding YJLV32 factory data when aluminium conductor is required.

Q.Can I use these ratings as a final cable-size calculation?

No. They are catalogue ratings. The project engineer must check installation conditions, grouping, derating, fault duty and local requirements.

Q.What should I send for a quotation?

Send the rated voltage, nominal section, total length, sheath requirement, destination port and required inspection documents.

Q.What are the factory's standard production terms?

For regular models, the factory guideline is 500–1,000 metres per specification and 10–15 days for production. Special customised constructions normally require 2,000–5,000 metres per specification. Production time does not include sea freight.

Related Technical Guides

Learn more about 11kV YJV32 SWA Cable specifications, installation, and sourcing.

SWA Cable Standards: IEC 60502 vs BS 5467 vs NFC 33-226 — Which Applies to Your Project?

Compare SWA cable standards across regions: IEC 60502 (international), BS 5467 (UK/Commonwealth), NFC 33-226 (Francophone Africa). Testing requirements, marking differences, and how to specify correctly for your market.

Read guide →

11kV Cable Specifications & Size Chart: Complete Current Rating Tables [2026]

Complete 11kV cable size chart with current ratings, dimensions, and weight tables. Single-core and 3-core XLPE 6.35/11kV cable specifications per IEC 60502-2. Copper and aluminium conductor options for underground and aerial installation.

Read guide →

Medium Voltage Cable 11kV & 33kV Manufacturer: Specifications & Factory Supply [2026]

11kV and 33kV medium voltage XLPE cable from our factory in Henan, China: single-core and 3-core, copper or aluminium conductor, copper screen, armoured and unarmoured, to IEC 60502-2. Specification tables, screen selection and factory-direct supply for utility and EPC buyers in Africa, the Middle East and Southeast Asia.

Read guide →

Underground Power Cable Types: Selection Guide by Voltage & Soil Condition [2026]

Compare underground power cable types by voltage (1kV–35kV) and soil condition. XLPE vs PVC, SWA vs STA armour, burial depth charts, thermal derating per IEC 60287. Request factory-direct quote within 24h.

Read guide →

11kV/415V Underground Cable Supply: BOQ, RFQ & Commissioning Guide

A procurement guide to 11kV/415V underground cable BOQs, RFQ clauses, supply boundaries, testing, commissioning and handover documents.

Read guide →

Ready to source 11kV YJV32 SWA Cable from the factory?

Send your specs — voltage rating / conductor size / cores / armour / length / destination port. Quote within 24 hours.

Checking compliance before you enquire? Factory ISO 9001 and CCC certificates with power cable type test reports. Product standards and certificates are confirmed per model, market and order.